DC Mode 4 charging stations allow electric vehicle owners to quickly charge their vehicles.
The stations can be made in the combined version Mode 4 + Mode 3 with a built-in cable with a TYPE 2 or 1 plug or a Type 2 connector with a locking mechanism.
Compatible with all electric vehicles equipped with CCS or CHAdeMO connectors.
The power of the station is determined by the software and can range from 30 kW to 400 kW, and the charging current can be from 70 A to 500 A.
SET charging stations can be used both in public and commercial facilities (company offices, apartment building parking lots, public parking lots, restaurants or hotels) and in the private sector. The housing of the charging station is made of stainless steel and meets the degree of protection IP54, the charging stations can be installed indoors and outdoors.
AC input parameters: | 30 kw | 50kw | 60kw | 80kw | 90kw |
Type of voltage | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases |
Rated voltage | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% |
Power frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
Input Current (Max) | 45 A | 80 A | 100 A | 130 A | 150 A |
Power | 30 kw | 50 kw | 60 kw | 80 kw | 90 kw |
Output parameters: | |||||
Options for installed connectors | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T |
Output power DC | 30 kw | 50 kw | 60 kw | 80 kw | 90 kw |
Output current DC | up to 70 A | up to 125 A | up to 150 A | up to 200 A | up to 200 A |
Output voltage DC max. | up to 1000 V | up to 750 V | up to 1000 V | up to 750 V | up to 1000 V |
Cable length | 4 meters | 4 meters | 4 meters | 4 meters | 4 meters |
Weather protection for connectors | + | + | + | + | + |
Disconnecting the connector after the session ends | + | + | + | + | + |
DC power meter | + | + | + | + | + |
Short circuit protection | + | + | + | + | + |
Protection against leakage current (RCD), diff. automatic | + | + | + | + | + |
Protection against overvoltage | + | + | + | + | + |
LxDxH (mm) | 400 x 500 x 2000 | 400 x 500 x 2000 | 400 x 500 x 2000 | 400 x 500 x 2000 | 400 x 500 x 2000 |
Mounting size (mm) | 400×500 | 400×500 | 400×500 | 400×500 | 400×500 |
Hidden location of fasteners | + | + | + | + | + |
Weight | ≤110 kg | ≤140 kg | ≤150 kg | ≤170 kg | ≤170 kg |
Degree of protection | IP 54 | IP 54 | IP 54 | IP 54 | IP 54 |
15 inch LCD display | + | + | + | + | + |
Stainless steel, vandal-proof housing with polymer coating | IK10 | IK10 | IK10 | IK10 | IK10 |
LED indication | + | + | + | + | + |
Temperature sensor | + | + | + | + | + |
Operating temperature range | -35…+50 °C | -35…+50 °C | -35…+50 °C | -35…+50 °C | -35…+50 °C |
Modular arrangement of components | + | + | + | + | + |
RFID/NFC, 13.56 MHz | option | option | option | option | option |
Mobile application | + | + | + | + | + |
Built-in payment system | + | + | + | + | + |
4G modem , Ethernet (RJ45/LSA+) | + | + | + | + | + |
Protocols | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON |
Emergency stop button | + | + | + | + | + |
Number of electric vehicles to be charged | 1 | 1 | 1 | 1 | 1 |
DC Mode 4 charging stations allow electric vehicle owners to quickly charge their vehicles.
The stations can be made in the combined version Mode 4 + Mode 3 with a built-in cable with a TYPE 2 or 1 plug or a Type 2 connector with a locking mechanism. Compatible with all electric vehicles equipped with CCS or CHAdeMO connectors.
The power of the station is determined by the software and can range from 30 kW to 400 kW, and the charging current can be from 70 A to 500 A.
SET charging stations can be used both in public and commercial facilities (company offices, apartment building parking lots, public parking lots, restaurants or hotels) and in the private sector. The housing of the charging station is made of stainless steel and meets the degree of protection IP54, the charging stations can be installed indoors and outdoors.
AC input parameters: | 120 kW | 150kw | 180kw | 210kw | 300kw | 350kw |
Type of voltage | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases | 3 phases |
Rated voltage | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% | 400 V ± 10% |
Power frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
Input Current (Max) | 200 A | 250 A | 300 A | 350 A | 500 A | 600 A |
Power | 120 kW | 150 kw | 180 kw | 210 kw | 300 kW | 350 kw |
Output parameters: | ||||||
Options for installed connectors | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T | CCS Combo2, CCS Combo1, CHAdeMO, GB/T |
Output power DC | 120 kW | 150 kw | 180 kw | 210 kw | 300 kW | 350 kw |
Output current DC | up to 325 A | up to 375 A | up to 425 A | up to 500 A | up to 500 A | up to 500 A |
Output voltage DC max. | up to 1000 V | up to 1000 V | up to 1000 V | up to 1000 V | up to 1000 V | up to 1000 V |
Cable length | 4 meters | 4 meters | 4 meters | 4 meters | 4 meters | 4 meters |
120 kW | 150kw | 180kw | 210kw | 300kw | 350kw | |
Weather protection for connectors | + | + | + | + | + | + |
CCS Combo convector liquid cooling | + | + | + | + | + | + |
Disconnecting the connector after the session ends | + | + | + | + | + | + |
DC power meter | + | + | + | + | + | + |
Short circuit protection | + | + | + | + | + | + |
Protection against leakage current (RCD), diff. automatic | + | + | + | + | + | + |
Protection against overvoltage | + | + | + | + | + | + |
LxDxH (mm) | 600 x 800 x 2000 | 600 x 800 x 2000 | 600 x 800 x 2000 | 600 x 800 x 2000 | 600 x 1300 x 2000 | 600 x 1300 x 2000 |
Mounting size (mm) | 600×800 | 600×800 | 600×800 | 600×800 | 600×1300 | 600×1300 |
Hidden location of fasteners | + | + | + | + | + | + |
Weight | ≤200 kg | ≤215 kg | ≤230 kg | ≤250 kg | ≤300 kg | ≤350 kg |
Degree of protection | IP 54 | IP 54 | IP 54 | IP 54 | IP 54 | IP 54 |
15 inch LCD display | + | + | + | + | + | + |
Stainless steel, vandal-proof housing with polymer coating | IK10 | IK10 | IK10 | IK10 | IK10 | IK10 |
LED indication | + | + | + | + | + | + |
Temperature sensor | + | + | + | + | + | + |
Operating temperature range | -35…+50 °C | -35…+50 °C | -35…+50 °C | -35…+50 °C | -35…+50 °C | -35…+50 °C |
Modular arrangement of components | + | + | + | + | + | + |
RFID/NFC, 13.56 MHz | option | option | option | option | option | option |
Mobile application | + | + | + | + | + | + |
Built-in payment system | + | + | + | + | + | + |
4G modem , Ethernet (RJ45/LSA+) | + | + | + | + | + | + |
Protocols | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON | OCPP 1.6JSON |
Emergency stop button | + | + | + | + | + | + |
Number of electric vehicles to be charged | 1-2 | 1-2 | 1-2 | 1-2 | 1-2 | 1-2 |